Article VGB PowerTech 12/2014

Compliance with the limit values for acid conductivity according to the VGB standard for steam and industrial power plants when conditioning with polyamines

For several years, various manufacturers have been offering online measuring devices for the continuous analysis and recording of the degassed acid conductivity. The installation of these analyzers makes it possible to distinguish between dissolved CO2 and other impurities as the cause of the increase in conductivity in the water-steam system. In the following, the monitoring of the limit values for the acid conductivity and the degassed acid conductivity using the appropriate online measuring technology in the amine mode of operation is illustrated using two practical examples.